Please use this identifier to cite or link to this item: http://172.16.16.104:8080/xmlui/handle/123456789/183
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShenava, Aashritha-
dc.contributor.authorMeshramkar, Roselene-
dc.date.accessioned2021-08-14T13:29:15Z-
dc.date.available2021-08-14T13:29:15Z-
dc.date.issued2020-
dc.identifier.urihttp://172.16.16.104:8080/xmlui/handle/123456789/183-
dc.description.abstractAim: The aim of the study was to evaluate the effect of mold temperature [room temperature (32°C), 450°C, and 790°C] on the fatigue deflection of clasps of commercially pure titanium. Materials and methods: Forty-five retentive wax profiles were cast in molds having three different mold temperature [room temperature (32°C), 450°C, and 790°C]. Specimens of grade 4 titanium, following the eligibility criteria, were selected. A 2-mm deflection test was done using an Instron machine and the flexibility of clasps of the respective groups was calculated. Deflection fatigue was tested using a cyclic-loaded custommade oscillating machine by calculating the number of loading cycles required to fracture the specimen. Results: The mean of flexibility of the clasp bars was observed and the difference was significant (between groups, F value was 38.49 at p = 0.0000 and within groups at p ≤ 0.01, respectively). The number of loading cycles applied to the clasp bars casted with 450°C and room temperature was more than that of 790°C, suggesting that the fatigue strength of clasps casted at 450°C and room temperature is more than that at 790°C. The mean of loading cycles of the clasp bars was observed and the difference was significant. Between groups, F value was 11.89 at p = 0.0001 and within groups at p ≤ 0.01. Conclusion: The number of loading cycles applied to the clasp bars casted with 450°C and room temperature was more than that of 790°C, and this suggests that the fatigue strength at 450°C and room temperature is more than that at 790°C. Temperature has an important role to play as the modulus of elasticity is higher at room temperature and 450°C than that at 790°C. Clinical implication: The ideal temperature for a titanium casting with relatively high fatigue strength would be 450°C mold temperature or room temperature. By investigating the fatigue deflection, it is clear that a desired undercut should be planned before clasp designing, considering the metal to be used.en_US
dc.description.sponsorshipWorld Journal of Dentistryen_US
dc.language.isoenen_US
dc.publisherJaypee Brothers Medical Publishersen_US
dc.subjectCasting technique,en_US
dc.subjectFlexural strength,en_US
dc.subjectMold temperature.en_US
dc.titleinvestigation into Effect of Mold Temperature on the Fatigue Deflection of Clasps of Commercially Pure Titanium An in vitro studyen_US
dc.typeArticleen_US
Appears in Collections:investigation into Effect of Mold Temperature on the Fatigue Deflection of Clasps of Commercially Pure Titanium An in vitro study



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.